Model | A12-010KEAA |
Battery Pack Parameter for Single Module | |
Combination method | 1P16S |
Nominal Capacity | 104Ah |
Nominal Energy | 5.32kWh |
Nominal Voltage | 51.2V DC |
Recommended Charging Voltage | 56.8V or 3.55V/any cell |
Internal Impedance | ≤40mΩ |
Standard Charge | 90A |
Standard Discharge | 90A |
Discharge Cut-off Voltage(Udo) | 43.2V |
Operation Temperature Range | Charge: 0~55℃ Discharge:-20~60℃ |
Storage Temperature Range | -20℃~60℃ |
Weight | 50±3kg |
Dimensions(W*D*Hmm) | 670*176*453 |
IP Grade | IP54 |
Inverter Parameter | |
Inverter power | 5000W |
Rated Energy | 10kWh |
AC input voltage | 220V(50-60Hz) |
AC output voltage | 220V(50-60Hz) |
PV Input Data | |
MPPT voltage range(V): | 120-500V |
Number of MPPT: | 1 |
General Data | |
Stackable quantity | 1-3(Each battery pack is 5.32KWh) |
Operating Temperature Range(℃) | 25~60℃, >45℃ Derating |
Cooling | Cooling |
Installation Style | Pile up |
Output Over Current Protection | Integrated |
Output Over Voltage Protection | Integrated |
PV Input Lightning Protection | Integrated |
Storage Temperature Range | -20℃~60℃(Recommend 25±3℃; ≤90%RH storage moisture range) |
Dimensions(W*D*Hmm) | 670*176*1510 |
Weight | 135±3kg |
IP Grade | IP54 |
Low-voltage All-in-one ESS Specification.pdf