● 90-264VAC or 102-370VDC Input
● 30mm ultra-thin height
● overvoltage, overcurrent, over temperature, undervoltage, short circuit protection
● high efficiency, low ripple
● operating temperature -30~+70℃
● highly capacitive load design, Stronger instantaneous load capacity
● Optional Current-sharing function
● high reliability, 100% full load burn-in test
● one year renewal, three-year warranty
| Model | HKI025-050NB | HKI025-120NB | HKI025-240NB | |
| Output | direct voltage/current | 5V/5A | 12V/2.1A | 24V/1A |
| voltage range | 3.3~5.3V | 12~15V | 24~28.5V | |
| current range | 0~7A | 0~3A | 0~1.5A | |
| stabilized voltage precision | ±2% | ±2% | ±2% | |
| ripple | <100mVp-p | <100mVp-p | <100mVp-p | |
| Input | least efficiency | 82% | 84% | 86% |
| voltage range | 90~264VAC;102~370VDC | |||
| surge current | Cold-boot<45A/230VAC | |||
| Protection | overvoltage | 115%-135%(rated voltage),re-power after fault removed | ||
| overcurrent | 120%-180%(rated current),re-power after fault removed | |||
| over temperature | OTP point to ensure that all components do not exceed the specified temperature,re-power after fault removed | |||
| undervoltage | AC input undervoltage protection point: <=60Vac, undervoltage protection recovery point: >=70Vac | |||
| short circuit | When the output terminal is short-circuited, the power supply cannot be damaged, cannot catch fire, and can automatically recover after the short-circuit is eliminated。 | |||
| Environment | operating temperature | -30~+70℃,5~85﹪RH,no condensation(please refer to derating curve) | ||
| reserving temperature | -40~+85℃,5~95﹪RH,no condensation | |||
| vibration | 10~500HZ,5G 10 min/cycle,60 min/X,Y,Z directions | |||
| Safety | safety standard | GB4943 EN62368 | ||
| electromagnetic compatibility standard | EN55032 Class B, GB9254 Class B,EN61000-4-2,3,4,5,6,8,11 , EN61000-3-2,3 | |||
| Withstand voltage | I/P-O/P:3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC | |||
| Other | dimensions | 79*51*28.8mm | ||
| package | 80pcs/17kg | |||