Model | HS200-12-NP | HS200-24-NP |
Output | direct voltage/current | 12V/16.5A | 24V/8.34A |
voltage range | 11.4~13.2V | 23.76~24.24V |
current range | 0.1~16.5A | 0.1~8.34A |
stabilized voltage precision | ±3% | ±3% |
ripple | <120mVp-p | <120mVp-p |
Input | least efficiency | 86% | 86% |
voltage range | 180~264VAC |
surge current | Cold-boot<70A/230VAC |
Protection | overload | 110%-150%(specified load),re-power after fault removed |
overvoltage | 115%-135%(rated voltage),Auto restart after fault removed |
Environment | operating temperature | -20~+60℃,20~90﹪RH,no condensation(please refer to derating curve) |
reserving temperature | -40~+85℃,10~95﹪RH,no condensation |
vibration | 10~500HZ,2G 10 min/cycle,60 min/X,Y,Z directions |
Safety | safety standard | UL60950-1,IEC60950-1,GB4943 |
electromagnetic compatibility standard | EN55022 Class B, GB9254 Class B,EN61000-4-2,3,4,5,6,8,11 , EN61000-3-2,3 |
Withstand voltage | I/P-O/P:3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC |
Other | dimensions | 199*98*40mm |
package | 20pcs/14.8kg |