| Model | HKI600-120PB | HKI600-240PB |
| Output | direct voltage/current | 12V/41.7A | 24V/21A |
| voltage range | 9.6~14.4V | 19.2~28.8V |
| current range | 0~41.7A | 0~21A |
| stabilized voltage precision | ±2% | ±2% |
| ripple | <100mVp-p | <150mVp-p |
| Input | least efficiency | 86% | 86% |
| voltage range | 90~264VAC;102~370VDC |
| surge current | Cold-boot<40A/230VAC |
| Protection | overvoltage | 115%-135%(rated voltage),re-power after fault removed | 115%-135%(rated voltage),Auto restart after fault removed |
| overcurrent | 120%-180%(rated current),re-power after fault removed |
| over temperature | OTP point to ensure that all components do not exceed the specified temperature,re-power after fault removed |
| undervoltage | AC input undervoltage protection point: <=60Vac, undervoltage protection recovery point: >=70Vac |
| short circuit | When the output terminal is short-circuited, the power supply cannot be damaged, cannot catch fire, and can automatically recover after the short-circuit is eliminated |
| Environment | operating temperature | -30~+70℃,20~90﹪RH,no condensation(please refer to derating curve) |
| reserving temperature | -40~+85℃,10~95﹪RH,no condensation |
| vibration | 10~500HZ,5G 10 min/cycle,60 min/X,Y,Z directions |
| Safety | safety standard | GB4943 EN62368 |
| electromagnetic compatibility standard | EN55032 Class B, GB9254 Class B,EN61000-4-2,3,4,5,6,8,11 , EN61000-3-2,3 |
| Withstand voltage | I/P-O/P:3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC |
| Other | dimensions | 230*127*40.5mm |
| package | 10pcs/14kg |