Model HK450-91PP | Input | 90-265VAC(47Hz-63Hz) 3A Max | |||
Output | Load Range | Voltage | Ripple & Noise | ||
Min | Max | ||||
+5V | 0.1A | 15A | ±5% | ≤50mV | |
+12V | 0.1A | 28A | ±5% | ≤120mV | |
+5VSB | 0A | 2A | ±5% | ≤50mV | |
+3.3V | 0.1A | 15A | ±5% | ≤50mV | |
-12V | 0A | 0.3A | ±10% | ≤120mV | |
Not exceeding 120W if combines +3.3V and 5V together | |||||
Standby Power Consumption | ≤3W | ||||
Protective Function | Over voltage protection, over power protection, over temperature protection, short circuit protection | ||||
Working Environment | Air Temperature:0~50℃,Relative Humidity:5%~85% without condensation | ||||
Storage Environment | Air Temperature:-40~70℃,Relative Humidity:5%~95% | ||||
EMI | Conform EN55022 Class B, GB9254 Class B | ||||
Earth Leakage Current | ≤3.5mA(264VAC/50Hz) | ||||
MTBF Value | ≥50K hours.Bellcore-TR-332(25℃) | ||||
Cooling Method | Forced cooling and fan cooling method | ||||
Package Method | 20PCS/Per Case | ||||
Typical Dimensions(mm) | 150(L)×80(W)×40(H) | ||||
Design Standards | Comply with Intel Flex 12V 1.0 Standard | ||||
Application | Network Server, IPC , etc. |