1. Complies with Intel Flex 12V standards
2. Adapted voltage range: 90-264VAC
3. Ball Fan, temperature control circuits
4. Overvoltage protection, overcurrent protection, short circuit protection
5. High reliability, 100% full load burn-in test
6. One year renewal, three-year warranty
| Rated Power 150W | Input | 90V-264VAC(47Hz-63Hz) 3A Max | |||
| Output | Load Range | Voltage | Ripple & Noise | ||
| Min | Max | ||||
| +5V | 0.5A | 10A | ±5% | ≤50mV | |
| +12V | 0.3A | 10A | ±5% | ≤120mV | |
| +5VSB | 0A | 2A | ±5% | ≤50mV | |
| +3.3V | 0.5A | 10A | ±5% | ≤50mV | |
| -12V | 0A | 0.3A | ±10% | ≤120mV | |
| Not exceeding 55W if combines +3.3V and 5V together | |||||
| Standby Power Consumption | ≤3W | ||||
| Protective Function | Overvoltage protection, overcurrent protection, short circuit protection | ||||
| Working Environment | Air Temperature: 0℃~50℃, Relative Humidity: 5%~95% without condensation | ||||
| Storage Environment | Air Temperature: - 40~70℃, Relative Humidity: 5%~100% | ||||
| EMI | Conform EN55032 ClassB and GB9254 ClassB | ||||
| Earth Leakage Current | ≤0.5mA(264VAC/50Hz) | ||||
| MTBF Value | ≥100K hours, MIL-HDBK-217F (25℃) | ||||
| Cooling Method | Forced cooling and dual ball fan cooling method | ||||
| Package Method | 20PCS/Per Case | ||||
| Typical Dimensions | 150(L)×80(W)×40(H)mm | ||||
| Design Standards | Complies with Intel Flex 12V 1.0 standards | ||||
| Application | Routers, firewalls, advertising machines, etc. | ||||