• Compatible with 4U rack-mount chassis installation
• Tested efficiency meets 80 Plus Gold energy efficiency requirements
• Low Ripple and Low Noise
• Side-Mounted Dual Ball Bearing Fan Design
• Operating Temperature Range: -20℃~60℃
• Multiple protection functions: OVP, OPP, SCP
| Model HK751-11PP | Rated Power | 650W | |||
| Input Parameters | 90-264VAC(47Hz-63Hz) 10A Max | ||||
| Output Parameters | Load Range | Voltage Regulation | Ripple & Noise | ||
| Min | Max | ||||
| +5V | 0.3A | 25A | ±5% | ≤120mV | |
| +12V | 1A | 54.1A | ±5% | ≤50mV | |
| +5VSB | 0.1A | 3A | ±5% | ≤50mV | |
| +3.3V | 0.3A | 25A | ±5% | ≤50mV | |
| -12V | 0A | 0.3A | ±10% | ≤120mV | |
| Combined Output Power for +5V & +3.3V≤130W | |||||
| Standby Power Consumption | ≤1.5W(5VSB/0.05A) | ||||
| Protection Functions | OVP, OPP, SCP | ||||
| Operating Temperature | Temperature: -20°C ~ 60°C; Relative Humidity: 5% ~ 85% (non-condensing) | ||||
| Storage Temperature | Temperature: -40°C ~ 70°C; Relative Humidity: 5% ~ 95% | ||||
| EMI | Compliant with EN55032 Class B, GB/T 9254 Class B | ||||
| Leakage Current to Ground | ≤3.5mA(264VAC/50Hz) | ||||
| MTBF | ≥50kh .MIL-HDBK-217F(25℃) | ||||
| Cooling Method | Forced air cooling with dual ball-bearing fan | ||||
| Packaging | 10units per carton | ||||
| Typical Dimensions | 140(L)×150(W)×86(H)mm | ||||
| Application Fields | 4U Industrial PC, Automation Equipment, Multi-control Equipment | ||||