● 6.2V~7.8V output power adjustment range
● natural cooling
● short circuit, overvoltage, overcurrent Protection
● 100% full load burn-in test
● one year renewal, three-year warranty
| Model | HKI408-068PB | |
| Output | direct voltage/current | 6.8V/60A |
| voltage range | 6.2~7.8V | |
| current range | 0~60A | |
| stabilized voltage precision | ±2% | |
| ripple | <50mVp-p | |
| Input | least efficiency | 86% |
| voltage range | 180-264VAC | |
| surge current | Cold-boot<80A/230VAC | |
| Protection | overcurrent | 72-102A |
| overvoltage | 8.5V-16V | |
| short circuit | When the output terminal is short-circuited, the power supply cannot be damaged, cannot catch fire, and can automatically recover after the short-circuit is eliminated | |
| Environment | operating temperature | -10~+70°C,5~85%RH, no condensation(please refer to derating curve) |
| reserving temperature | 35~+75°C,5~95%RH, no condensation | |
| vibration | 10~500HZ,5G 10 min/cycle,60 min/X,Y,Z directions | |
| Safety | safety standard | GB4943, IEC62368-1 approved |
| electromagnetic compatibility standard | EN55022 ClassA,GB9254 Class A,EN61000-4-2,3,4,5,6,8,11,EN61000-3-2,3 | |
| Withstand voltage | I/P-0/P:3KVAC I/P-FG:2KVAC O/P-FG:05KVAC | |
| Other | dimensions | 215*115*50mm |
| package | 12pcs/14kg | |