| Model | HK500-12FP | |||||
| Output | DC voltage/ Current | 12V/30A | 5V/15A | 3.3V/15A | 5Vsb/2A | -12V/0.3A |
| Voltage Adjustment Range | 11.4-12.6 | 4.75-5.25 | 3.135-3.465 | 4.75-5.25 | 10.8-13.2 | |
| Current Adjustment Range | 1-30A | 0.3-15A | 0.5-15A | 0.05-2A | 0-0.3A | |
| Voltage Accuracy | ±5% | ±5% | ±5% | ±5% | ±10% | |
| Ripple | <120mV | <50mV | <50mV | <50mV | <120mV | |
| Input | Minimum Efficiency | 70% | ||||
| Voltage Range | 180-265VAC | |||||
| Surge Current | less than the ratings of its critical components (including bulk rectifiers, fuses, and surge limiting device) under all conditions of line voltage of 180-265Vac | |||||
| Protection | Over-load | 440-640W,latch | ||||
| Over-voltage | +5V<7V、 +12V<15.6V、+3.3V<4.7V | |||||
| Environment | Operating Temperature/ Humidity | 0~+40℃,5~85﹪RH,no condensation | ||||
| Storage Temperature/ Humidity | -40~+55℃,5~95﹪RH,with condensation | |||||
| Vibration | 5 to 17 Hz 0.048 inch double amplitude displacement、17 to 199 Hz 0.73Gs acceleration、200 to 500 Hz 0.33Gs acceleration、Frequency to be swept at a rate of 0.067 decades/minute (4 decades/hour). Dwell at resonant frequencies for 30 minutes. | |||||
| Production Compliance | Safety standards | GB4943.1-2011、GB17625.1-2012、GB/T9254-2008 | ||||
| EMC Standards | EN55022 Class B | |||||
| Hi-POT | Input to GND: Voltage 1800VAC Time 3.0S | |||||
| Other | Dimensions | 150*140*86mm | ||||
| Package | 10PCS/13KG | |||||